Chelora Chemicals is a copper oxychloride 50% WP supplier and sourcing partner serving distributors and registrants across the United States, with suspensibility, sieve residue and UN 3077 documentation agreed before dispatch.

  • 50% Cu AS METAL
  • ≈850 g/kg COMPOUND
  • FRAC M1 MULTI-SITE
  • SUSPENSIBILITY SPECIFIED
  • UN 3077 CLASS 9
  • HS 3808 92
Product Identity Available to order
CAS Number (active)
1332-65-6
Formulation type
Wettable powder — WP
Copper as Cu
50% w/w
Copper oxychloride content
≈ 850 g/kg (85.0%)
Molecular formula (active)
Cu₂(OH)₃Cl
FRAC group
M1 — multi-site contact
Appearance
Green to blue-green powder
Transport
UN 3077 · Class 9 · PG III
HS Code
3808 92

Note: read the percentage carefully — this is the single most common ordering error on copper fungicides. The 50% here is copper expressed as metal, the convention used on FAO specifications and on US labels, which works out to roughly 850 g/kg of copper oxychloride compound. Some trade listings instead use the compound percentage, which is why the same material is sold elsewhere as "850 WP". If a quote does not state the basis, it is not a quote — we state both.

50%Copper as metal
850g/kg copper oxychloride
M1FRAC group
3077UN number
Where it sits

From technical grade to wettable powder

A WP is a milled and surfactant-blended dispersion system. The chemistry is set upstream; the formulation decides whether it actually sprays.

Copper sourceSpent cupric chloride etchant Technical gradeCopper Oxychloride Technical1332-65-6 Milling & blendingWetting agent · dispersant · carrier This productCopper Oxychloride 50% WP1332-65-6 ApplicationFoliar spray · the global standard copper loading

Why it matters: 50% copper as metal is the same thing as "850 WP" — one market states copper, the other states compound, and the material is identical

Product overview

What copper oxychloride 50% WP is used for

Copper oxychloride 50% WP is the world standard copper fungicide loading — a wettable powder carrying 50% copper expressed as metal, which is roughly 850 g/kg of copper oxychloride compound. It is a contact fungicide and bactericide, meaning it protects the surface it lands on and does not move systemically in the plant.

Its enduring commercial importance is resistance management. Copper is FRAC group M1, a multi-site inhibitor: it acts on several biochemical targets at once rather than one, which is why pathogens have not developed resistance to it the way they have to single-site chemistry. That makes it a program anchor rather than a legacy product — the thing a spray program rotates back to in order to protect the modern actives.

What the formulation specification controls

  • Copper as Cu, 50% w/w. The declared active content, equivalent to roughly 850 g/kg of compound.
  • Suspensibility. How much stays dispersed in the spray tank after standing — the parameter that decides field performance.
  • Wet sieve residue and wettability. A WP that will not wet out or that blocks nozzles is a rejected lot regardless of assay.
  • The technical grade behind it: copper oxychloride technical.

Handling character

Copper oxychloride WP is a Class 9 dangerous good on aquatic toxicity grounds. Full detail is in the Safety section below.

Typical WP formulation specification
ParameterTypical value
AppearanceGreen to blue-green free-flowing powder
Copper as Cu50% w/w ± tolerance
Copper oxychloride≈ 850 g/kg
SuspensibilityPer agreed specification
Wet sieve residuePer agreed specification
Wettability & pHPer agreed specification

Important: the figures above are indicative of commercial material and are offered for planning only. The batch certificate of analysis is the governing document.

Physical & chemical properties
PropertyValue
Physical stateGreen to blue-green powder
Active molecular weight213.57 g/mol
Water solubility (active)Insoluble — forms a suspension
Mode of actionMulti-site contact; FRAC M1
Spray water pHDo not buffer below pH 6
Tank behaviorSuspension — requires agitation
Active density3.5 g/cm³

Figures compiled from public reference data for CAS 1332-65-6 and from published copper oxychloride WP label specifications, rounded for readability. Suspensibility, wet sieve and wettability are formulation parameters agreed per order rather than fixed constants. Treat the table as orientation, not as a specification.

Applications

Where the 50% loading is specified

The standard commercial grade for distribution, resistance-management programs and registrant supply.

Broad-spectrum disease control

Used against bacterial and fungal diseases on citrus, grapes, potatoes, tomatoes, coffee, pome and stone fruit, mangoes, peppers and cucurbits in markets where it is registered.

  • Suspensibility specified
  • Consistent copper assay
  • Label claims are registrant-specific

Resistance management programs

FRAC M1 multi-site activity makes copper the rotation anchor that protects single-site actives from resistance development.

Distributor & retail packing

Packed into 1 kg and 5 kg retail units to your approved label artwork where you hold the product registration.

  • Artwork to your registrant label
  • Cartoned retail packs
  • UN 3077 marking throughout

Registrant & toll supply

Supplied in bulk to registrants and repackers who hold their own product registration and label.

  • 25 kg bags and bulk bags
  • Specification held across the contract
  • Second formulator qualified in reserve

Import & FIFRA coordination

A pesticide import needs a Notice of Arrival on EPA Form 3540-1, and US sale or use needs an EPA-registered product. We coordinate with your broker.

  • NOA coordination with your broker
  • UN 3077 documentation prepared
  • Registration remains yours

Seasonal contract supply

Copper demand tracks the spray calendar, so contracted tonnage with call-off scheduling is how this line is normally bought.

  • Annual contracts with call-off
  • Price held across the contract
  • Second source held in reserve
United States coverage

Delivered to US plants and ports

We ship copper oxychloride 50% WP to nominated delivery points across the United States. The regions below are destinations we serve — Chelora Chemicals is a sourcing and supply partner, not a US manufacturer, and does not hold US stock.

Gulf Coast

The largest US chemical cluster, and the usual entry point for bulk consignments.

  • Houston & Galveston, TX
  • New Orleans & Baton Rouge, LA
  • Mobile, AL

Northeast

Container and bulk delivery into the mid-Atlantic and New England manufacturing belt.

  • Newark & Elizabeth, NJ
  • Philadelphia, PA
  • Boston, MA

Southeast

Port-side delivery for the Carolinas, Georgia and Florida processing plants.

  • Savannah, GA
  • Charleston, SC
  • Jacksonville, FL & Norfolk, VA

Midwest & Great Lakes

Inland rail and truck forwarding from the nearest coastal port to the industrial Midwest.

  • Chicago, IL
  • Detroit, MI
  • Cleveland & Columbus, OH

West Coast

Pacific routing for West Coast processors and formulators.

  • Los Angeles & Long Beach, CA
  • Oakland, CA
  • Seattle & Tacoma, WA

Southwest & Mountain

Inland delivery to interior states, forwarded from the Gulf or Pacific gateway.

  • Dallas–Fort Worth, TX
  • Phoenix, AZ
  • Denver, CO

Importing into the United States

Copper oxychloride 50% WP is a TSCA-regulated chemical substance. Under TSCA section 13 the importer of record, or its authorized agent, must certify to US Customs and Border Protection that each shipment either complies with TSCA or is not subject to it. We confirm the substance's TSCA Inventory status and agree in writing who files that certification before the first consignment moves.

Which party carries that duty follows the Incoterm. On FOB, CFR or CIF terms it is usually the US buyer; on DDP terms it can be the seller or its agent. Safety data sheets and labels are supplied to OSHA's updated Hazard Communication Standard, and the UN 3077 Class 9 transport documentation is prepared before booking.

  • TSCA IMPORT CERTIFICATION
  • OSHA HAZCOM SDS & LABELS
  • UN 3077 · CLASS 9 · PG III
  • US CUSTOMS DOCUMENTATION
US delivery at a glance
ItemHow it works
Delivery pointsAny nominated US plant, terminal or port of discharge
Incoterms quotedFOB · CFR · CIF · DDP
Importer of recordAgreed in writing before the first shipment
TSCA certificationSection 13 positive certification filed at entry
DocumentationBatch COA, SDS, packing list, certificate of origin
Pack formats25 kg bags or 1 kg–5 kg retail packs

Note: regional coverage describes where we deliver, not where we hold inventory. Lead time depends on producer scheduling and ocean transit to your nominated US port — we confirm both in the quotation.

Buying from Chelora

How we supply copper oxychloride 50% WP

Chelora Chemicals is a copper oxychloride WP supplier and sourcing partner, not a manufacturer. On a formulated product the assay is the easy part. What decides whether a lot performs is suspensibility, wettability and sieve residue — and we agree those before quoting, not after a field complaint.

We place your order with whichever qualified formulator best matches your specification, your price point and your delivery window, and we settle the FIFRA and import position before booking rather than after.

We are direct about the limit of what a supplier can do here: we do not hold EPA product registrations and cannot lend one. If your intended use needs a registered product in the US, that registration has to be yours.

  • The percentage basis stated both ways on every quote. 50% copper as metal, ≈850 g/kg as compound — the ambiguity in trade listings is the commonest cause of a wrong order on this product.
  • Suspensibility and wet sieve agreed up front. These are what decide field performance and nozzle behavior, and they are not visible in a copper assay figure.
  • UN 3077 documentation prepared before booking. Marked packaging, a dangerous goods declaration and compliant paperwork — not assembled at the dock.
  • FIFRA position settled honestly. A pesticide product must itself be EPA-registered for US sale or use, and an imported pesticide needs a Notice of Arrival on EPA Form 3540-1. We coordinate; we do not register.
  • Label and pack artwork to your registrant. Where you hold a registration, packaging is produced to your approved label rather than to a generic one.
  • Batch traceability to the producing formulator. Full chain of custody documentation on request.
Packing & logistics

Bagged, or in retail packs

25 kg bags, bulk bags or small retail packs — all to UN 3077 marking and labeling requirements.

Bags

25 kg poly-lined bags

Moisture-barrier bags on stretch-wrapped pallets, UN-marked, the standard commercial unit.

Retail packs

1 kg · 5 kg sealed packs

Small sealed packs in cartons, produced to your approved label artwork where you hold the registration.

FIBC

500–1,000 kg bulk bags

Liner-fitted bulk bags for repacking operations and large-scale distribution.

Drums

Fiber drums

Sealed fiber drums where extra moisture protection or extended storage is needed.

FOB · CIF · CFR · DDP

Incoterms to suit you

Quoted on the Incoterm your purchasing team works to, with dangerous goods documentation filed before booking.

Small trial packs

Trial / sample quantities

Small packs dispatched for suspensibility, compatibility and spray trials before a commercial order.

Safety, storage & handling

A Class 9 dangerous good - the aquatic hazard drives it

Copper oxychloride is moderately hazardous by ingestion and inhalation, and the classification that governs its logistics is aquatic toxicity. It is very toxic to aquatic life with long-lasting effects, which is what makes it a Class 9 dangerous good rather than an unregulated solid. The summary below is orientation only - the safety data sheet supplied with your specific batch is the authoritative document.

GHS Signal word: Warning

Classified hazards

  • H302Harmful if swallowed.
  • H332Harmful if inhaled.
  • H315Causes skin irritation.
  • H410Very toxic to aquatic life with long lasting effects.

US registration and import, stated plainly. Copper oxychloride is an EPA-recognized pesticide active ingredient (PC code 023501) covered by the agency's copper reregistration decision, and a technical grade product appears in EPA's product label system. That is not the same as a licence to sell or apply a formulated product here: under FIFRA a pesticide product must itself be EPA-registered for US sale or use, that registration sits with the registrant and never with a raw material supplier, and an imported pesticide requires a Notice of Arrival, EPA Form 3540-1, filed with Customs. We supply material and documentation and will coordinate with your broker; we do not hold registrations and we will not tell you that you can apply unregistered material.

Storage

Store in sealed original packaging in a cool, dry, well-ventilated area, away from food, seed and feedstuffs, and away from strong acids. Keep off the floor and protect from moisture: damp material cakes, and the beta crystal form cakes more readily than the alpha form. Bunded or contained storage is advised because of the aquatic hazard.

Handling

Handle with dust control, impervious gloves, eye protection and respiratory protection where dust is generated; the material is harmful if swallowed or inhaled and irritates skin. Wash hands and face after handling. Prevent any release to drains, watercourses or soil. Follow the exposure controls set out in the batch SDS.

Transport

Copper oxychloride and its formulations are classified as dangerous goods for transport on the basis of aquatic toxicity, normally shipped as UN 3077, Environmentally hazardous substance, solid, n.o.s., Class 9, Packing Group III. This is a real difference from most of our inorganic range: marked and labeled packaging, a dangerous goods declaration and IMDG or DOT-compliant documentation are required. We confirm and document the classification for your specific grade, packaging and destination before booking.

Quality assurance

Every batch, documented

We verify documentation before dispatch so there are no surprises at your incoming-goods bench.

Specification agreed

Copper content basis, crystal form, shade, particle size and moisture confirmed against your requirement before order placement.

Producer batch testing

The producing plant tests each batch against the agreed specification before release.

Documentation review

COA, SDS, TSCA or FIFRA position and UN 3077 dangerous goods paperwork checked by our desk before the shipment is booked.

Traceable dispatch

Each shipment is traceable to its producing batch, with full chain-of-custody records on request.

Production background

How a copper oxychloride WP is built

A wettable powder is a dispersion system, not a solution. Copper oxychloride is insoluble in water, so the formulation has to hold insoluble particles suspended in a spray tank long enough to be applied evenly. That is achieved by milling the technical grade to a controlled particle size and blending it with a wetting agent, a dispersant and an inert carrier.

The declared content is copper expressed as metal, following FAO specification and US label convention. At 50% copper as Cu that corresponds to roughly 850 g/kg of copper oxychloride compound, since technical grade itself carries about 59% copper. The remainder is carrier and surfactant system. This is exactly why the same formulation appears in some markets as "850 WP" — the compound basis — and why a quote that does not state the basis is not usable.

Copper oxychloride is a multi-site contact fungicide, FRAC group M1. It acts on several biochemical targets rather than one, which is why resistance to it has not developed the way it has to single-site chemistry — and why copper remains a resistance-management anchor in spray programs rather than a legacy product. One formulation note from published labels: do not buffer the spray water below pH 6.

We do not publish operating process parameters here; this is background only. Full technical documentation accompanies every shipment, and any process-specific detail you need is best confirmed directly with our technical desk.

Quick reference
Formulation typeWettable powder — WP
Declared basisCopper expressed as metal
Compound equivalent≈ 850 g/kg copper oxychloride
Mode of actionMulti-site contact — FRAC M1
Tank requirementSuspension; requires agitation
Spray waterDo not buffer below pH 6
Frequently asked

Copper oxychloride 50% WP, answered

What does the 50% in copper oxychloride 50% WP mean?
It means 50% copper expressed as metal, which is the convention used on FAO specifications and on US pesticide labels. That corresponds to roughly 850 g/kg of copper oxychloride compound, because technical grade copper oxychloride itself carries about 59% copper. The same formulation is sold in some markets as "850 WP" on the compound basis. This is the commonest ordering error on copper fungicides, so we state both figures on every quote.
Is copper oxychloride 50% WP the same as 850 WP?
Yes. They are the same material described on two different bases. "50% WP" states copper as metal at 500 g/kg; "850 WP" states copper oxychloride compound at 850 g/kg. Published labels confirm the equivalence directly, declaring 850 g/kg copper oxychloride and 500 g/kg metallic copper equivalent on the same product.
What is FRAC group M1 and why does it matter?
FRAC M1 means multi-site contact activity. Copper acts on several biochemical targets in the pathogen at once rather than on a single enzyme, so pathogens cannot adapt to it by a single mutation the way they can to single-site chemistry. That is why resistance to copper has not developed broadly after a century of use, and why copper functions as a rotation anchor in a spray program - protecting the modern single-site actives rather than competing with them.
What is the difference between the 50% and 35% WP?
The copper loading. The 50% grade carries 50% copper as metal, about 850 g/kg compound; the 35% grade carries 35% copper as metal, about 595 g/kg compound. The 50% grade is the global standard and delivers more copper per unit weight, so it is the usual choice for general commercial supply. The 35% grade is specified where a lower copper load per hectare is wanted, including on phytotoxicity-sensitive crops, and where it is being co-formulated or blended with other actives.
Which specification parameters actually matter?
Beyond the copper assay, three formulation parameters decide whether the product performs: suspensibility, which is how much active stays dispersed in the spray tank after standing; wet sieve residue, which decides whether it blocks nozzles; and wettability, which decides whether it disperses at all on tank fill. None of these are visible in a copper assay figure, so we agree them before quoting rather than after a field complaint.
Is it dangerous goods to ship?
Yes. Copper oxychloride is very toxic to aquatic life with long-lasting effects, which makes the formulation UN 3077, Environmentally hazardous substance solid n.o.s., Class 9, Packing Group III. Marked and labeled packaging, a dangerous goods declaration and compliant documentation are required. We prepare that paperwork before booking rather than at the dock.
Can I sell or apply this in the United States?
Only if the specific product is EPA-registered. Under FIFRA a pesticide product must itself hold a registration for US sale or use, and that registration sits with the registrant, never with a raw material or formulation supplier. An imported pesticide also requires a Notice of Arrival on EPA Form 3540-1 filed with Customs. Copper oxychloride is an EPA-recognized active ingredient, PC code 023501, but that is not the same as a product registration. If you hold one, we supply to your approved label; if you do not, we will tell you so plainly.
Do you hold the EPA registration?
No, and no supplier can lend one. We supply material, a certificate of analysis, a safety data sheet and dangerous goods documentation, and we will produce packaging to your approved label artwork where you hold the registration. We will not suggest that unregistered product can be sold or applied in the United States.
What packing do you offer?
25 kg poly-lined moisture-barrier bags on stretch-wrapped pallets as the standard commercial unit, 1 kg and 5 kg sealed retail packs in cartons produced to your approved label artwork, 500 to 1,000 kg bulk bags for repacking operations, and sealed fiber drums where extra moisture protection is needed. All packaging carries UN 3077 marking and labeling.
Do you supply copper oxychloride 50% WP in the United States?
Yes, to registrants, repackers, distributors and ports across the United States, including the Gulf Coast, Northeast, Southeast, Midwest, West Coast and Southwest. Chelora Chemicals is a sourcing and supply partner rather than a US manufacturer or registrant, so material is placed with a qualified formulator and shipped to your nominated US delivery point on the Incoterm your purchasing team works to.
Ready to order?

Get a quote on copper oxychloride 50% WP

Send us your required copper basis, suspensibility and sieve specification, pack format and US delivery point — and tell us whether you hold a product registration, because that decides the import route. We will come back with a firm quote, lead time and full documentation.

Emailsource@cheloragroup.com
Phone / WhatsApp+91 98191 11179
Delivering toAll United States regions
Response timeWithin one business day